The Centurion is a True Online Double Conversion UPS designed to provide comprehensive power protection for critical equipment. Versatile software management and hardware options offer the flexibility to build up a power protection solution to fit any application.

Meticulously developed by PowerShield engineers to be a world leading technology UPS, the Centurion Tower addresses absolutely all requirements and features as has been demanded by the sophisticated Australian power consumer and hence stands in a class of its own, as a world leading UPS technology.

SKU: PSCE1000 Categories: ,

Exceptional Surge Protection
• Offering the best protection in its class to protect against damaging surges.
Output Power Factor
• The Centurion Tower is a high-density UPS with output power factor (PF=0.9) to provide higher performance and efficiency to critical applications.
Informative & easy-shift LCD display
• The front panel LCD display panel is readily viewable and displays all critical and noncritical parameters, including the estimated battery backup time remaining.
Programmable outlets
• This UPS comes with programmable power management outlets allowing the user to control the load segments, thereby extending battery backup times to mission critical devices by shutting down non-critical items.
Emergency Power Off Function (EPO)
• This feature can turn off and isolate the UPS in the event of fires or other emergencies.
Advanced ECO Mode
• It has an advanced ECO mode, which allows the UPS to operate at a very high efficiency, up to 98%. When the utility mains input voltage is within the ECO range the UPS saves energy by passing the mains supply directly through to the load, while the inverter continues to operate in a passive mode.

Battery Bank Extension Options
• The Centurion Tower provides the option to increase battery backup time by simply adding additional battery banks.

Model PSCE1000 (L)
Capacity  1000VA/900W
Topology True online double – conversion

INPUT
Nominal Voltage 200/208/220/230/240 VAC
Voltage Range
110 – 300 VAC ±5% at 50% Load, 160 – 300 VAC ± 5% at 100% Load
Frequency Range 40Hz ~ 70Hz
Phase Single phase with ground
Power Factor ≥0.99 @ 100% load

OUTPUT
Output Voltage 240VAC (Selectable 200/208/220/230/240 Vac)
Frequency Range (Synchronized Range) 47~53Hz or 57~63Hz (Auto detect)
Frequency Range (Batt. Mode) 50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion ≥2% THD (Linear Load),  ≥4% THD (Non-Linear Load

Transfer
AC Mode to Batt. Mode Zero
Inverter to Bypass 4ms (Typical)

Waveform (Batt. Mode) Pure Sine Wave

EFFICIENCY
AC Mode 90%
Eco Mode 98%
Battery Mode 89%

BATTERY
Battery Type 12V50W(x3)
Typical Recharge Time 4 hours to recover to 90% capacity
Charging Current (max.) 1.5A
Long Run Models 1/2/4/8A Selectable via LCD
Charging Voltage (nominal) 36 VDC

PROTECTION
Full Protection 1248 Joules/39000 Amps

COMMUNICATIONS & MANAGEMENT
Interface USB or RS232 as standard. Intelligent slot for PSSNMPV4 or PSAS400 dry contact or PSMBUS
Software PowerShield NetGuard® Software – supports Windows based operation systems, Linux, Unix & Mac
LCD Display/Alarm UPS Status, Load Level, Battery Level, Input/Output Voltage, Battery Time Remaining and Fault Indicators
Audible Alarm Battery Mode, Low Battery, Overload, Fault

PHYSICAL
Dimensions (D x W x H) 396 x 145 x 240 mm
Weight Standard/L 12.5kg/5.8kg

OPERATING ENVIRONMENT
Humidity x Temperature 20-95% (RH non-condensing) @ 0-40°C
Noise Level Less than 50dBA @ 1 metre

COMPLIANCE
Safety EN62040-1-1 2003, IEC60950-1-1
EMS EN62040-2 2006
RoHS Directive 2001/65/EU

PowerShield Centurion Tower Brochure

PowerShield Centurion Tower User Manual

Optional Accessories

  • PSSNMP – SNMP Network Management card 
  • PSEMD – Environmental Monitoring Device for temperature & humidity
  • PSModbus – Modbus card 
  • PSAS400 – AS400 dry contact relay card 
  • PSCEBB6 – Extra battery bank 